Installation, Testing & Commissioning: done once, done right.

A certified device is only half of compliance. ZAN-F's engineering team executes the other half: precision installation, verified testing, and documented commissioning.

AMC & support

// The four-stage process

From site survey to compliance handover.

Each stage has a clear scope and a clear output. Select a stage to see the detail.

  1. 01

    Site Survey & Engineering

    We assess the exhaust line, calculate back-pressure and size the RECD for your DG set.

    • Exhaust line assessment
    • Back-pressure calculation
    • RECD sizing & mounting design
    • Structural and space feasibility
  2. 02

    Supply & Installation

    Genuine Platino hardware, erected and integrated by our crew to safety-compliant standards.

    • Mechanical erection
    • Exhaust integration
    • Insulation & cladding
    • Electrical / OBD panel wiring
    Learn more about Supply & Installation
  3. 03

    Testing & Verification

    Measured, not assumed. We verify performance under load before anything is signed off.

    • Back-pressure measurement
    • Emission performance checks
    • OBD calibration
    • Load-condition trials
    Learn more about Testing & Verification
  4. 04

    Commissioning & Handover

    Performance demonstration and a documented compliance pack, ready for any audit.

    • Performance demonstration
    • Compliance documentation pack
    • Operator briefing
    • Warranty registration
    Learn more about Commissioning & Handover

// Handover

What you receive at handover.

Every ZAN-F project closes with a documentation pack. It is what you show an auditor, a regulator or the next facility manager.

Deliverables checklist

  • Site survey report and RECD sizing
  • Installation photographs
  • Back-pressure and performance test reports
  • OBD calibration record
  • Manufacturer certificates
  • Operator briefing record
  • Warranty registration
  • AMC schedule (if contracted)

// Who we serve

Sites where DG sets cannot fail.

Data centers

Uptime-critical DG fleets

Hospitals

Compliance without downtime

Manufacturing

Plant-room and yard DG sets

Commercial buildings

Towers, malls and offices

IT parks

Multi-DG campuses

Infrastructure

Airports, metros and utilities